Problem: The Focus™ stops producing steam.
Solution: Bypass the Manual Thermostat on the steam kettle.
Required equipment:
- Phillips screwdriver or drill and drill bit
- Crimp wire connector
- Wire cutters/crimper
How to do it:
Step 1: Unscrew the top two screws on the front plate of the unit in order to open up the unit.
Step 2: Disconnect the two white wires from the Manual Thermostat.
Step 3: Cut off the connector from each white wire. Strip the wire coating about 1/4" back on both wires.
Step 4: Crimp together the two white wires with a crimp connector.
Step 5: Close up the machine and replace the two top screws in the front faceplate.