Problem: The Focus™ stops producing steam.


Solution: Bypass the Manual Thermostat on the steam kettle.


Required equipment:

  • Phillips screwdriver or drill and drill bit
  • Crimp wire connector
  • Wire cutters/crimper


How to do it:

Step 1: Unscrew the top two screws on the front plate of the unit in order to open up the unit.


Step 2: Disconnect the two white wires from the Manual Thermostat.


Step 3: Cut off the connector from each white wire. Strip the wire coating about 1/4" back on both wires.


Step 4: Crimp together the two white wires with a crimp connector.


Step 5: Close up the machine and replace the two top screws in the front faceplate.